Dyneema

Category Type Material
Fibers Synthetic Fibers

show all Fibers types

Aramid (High Modulus Grade)
Aramid (Standard Grade)
Dyneema
Nylon fiber
Polyester fiber

Data Table for: Fibers: Synthetic Fibers: Dyneema

Mechanical Properties

Quantity Value Unit
Young's modulus 55000 - 172000 MPa
Tensile strength 1400 - 3090 MPa
Elongation 2.7 - 4.5 %
Yield strength 1400 - 3090 MPa

Physical Properties

Quantity Value Unit
Thermal expansion -12 - -12 e-6/K
Thermal conductivity 20 - 20 W/m.K
Melting temperature 144 - 152 °C
Service temperature -200 - 100 °C
Density 960 - 990 kg/m3
Resistivity 1000000000000 - 100000000000000 Ohm.mm2/m
Breakdown potential 90 - 90 kV/mm
Dielectric loss factor 2.25 - 2.3

Environmental Data

Quantity Value Unit
Author: Idemat 2003, Design for Sustainability, Delft University of Technology

General

     
Synonyms Ultra-high-molecular-weight polyethylene (UHMWPE), high-modulus polyethylene (HMPE), high-performance polyethylene (HPPE)
Remarks Good resistance against chemicals and impact (damage tolerant). Due to fibrilar structure, very different longitudinal and transverse properties. Fibres are linear elastic to failure. Data are for untwisted yarn.